Equinox Systems MEGAPLEX Manual de usuario Pagina 75

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 238
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 74
AMIS Analog Networking
585-300-512 Issue 7
May 1999
AUDIX Administration
3-23Implementation
3
Figure 3-8. AMIS Casual Addressing to Local Numbers
Localrl STATUS: alarms: none, logins: 1, thresholds: none
PATH: system : translation : machine : audix/amis/call delivery
Error and confirmation information appears on this line.
machine name: localnums_ local/remote: r password: ________ ext length: 7
voiced name (y/n)? y voice id: 3 AMIS callback no.: 1 (1, 2, 3, 4, or 5)
default community: 1 connection type: amisac data rate: _____ channel: _
dial string: 9
address ranges (prefix start / end extension) warnings
1: 7____________________ 0000000___ / 9999999___
2: _____________________ __________ / __________
3: _____________________ __________ / __________
4: _____________________ __________ / __________
5: _____________________ __________ / __________
6: _____________________ __________ / __________
7: _____________________ __________ / __________
8: _____________________ __________ / __________
9: _____________________ __________ / __________
10: ____________________ __________ / __________
message transmission schedule (hh:mm)
1. start: 08:00 end: 17:59 interval: __:__ updates (y/n)? in n out n
2. start: __:__ end: __:__ interval: __:__ network turnaround (y/n)? n
3. start: __:__ end: __:__ interval: __:__ log connect events (y/n)? n
new machine name: ______________ send to non-administered recipients (y/n)? y
CHANGE
or RUN
ADD DELETE CLEAR
FORM
EXIT ENTERHELP FIELD
HELP
Vista de pagina 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 237 238

Comentarios a estos manuales

Sin comentarios