CobraNet Programmer’s Reference
Management Interface Variable Reference
DS651PM25 ©Copyright 2006 Cirrus Logic, Inc. 73
Name
flashTDirection
Description
Specifies whether the transaction is a flash sector read, write or erase.
0 - Read flash to transmit buffer
1 - Write flash from transmit buffer
2 - Erase flash sector
Host Address
0x1204
SNMP Object Identifier
Not available via SNMP
Type
Integer
Attributes
Read/Write
Implemented Version
2.8.6