Equinox Systems Cirrus Manual Pagina 112

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 147
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 111
112 ©Copyright 2006 Cirrus Logic, Inc. DS651PM25
CobraNet Programmer’s Reference
Management Interface Variable Reference
Name
syncStatus
Description
Indicates current audio clock synchronization status. The following values may be ORed together:
Unspecified bits should be ignored.
0x01 - Locked to external or network clock reference.
0x02 - Valid clock present at REFCLK_IN.
0x04 - MUTE is not asserted. Indicates proper operation of CobraNet interface as MUTE is
asserted on detection of a fault condition or loss of connection to the network.
Host Address
0x61000
SNMP Object ID
1.3.6.1.4.1.2680.1.1.8.5
Type
Integer
Attributes
Read-only
Default Value
n.a.
Implemented Version
Variable implemented 2.5.9. EXTWRDCLKOUT presence indication added 2.6.4.
Name
syncCounter
Description
Incremented each time network sync is lost.
Host Address
0x61001
SNMP Object ID
1.3.6.1.4.1.2680.1.1.8.6
Type
Counter
Attributes
Read-only
Default Value
0
Implemented Version
2.6.5
Name
syncNTime
Description
CobraNet network time. Advances 256 every 1-1/3ms. Network time rolls over after reaching
0xFFFF00 (16,776,960) on 24- and 32-bit platforms.
Host Address
0x61002
SNMP Object ID
1.3.6.1.4.1.2680.1.1.8.7
Type
Integer (Only lower 24 bits are valid. Upper byte is always zero.)
Attributes
Read-only
Implemented Version
2.9.9 (2.10.4 for CS18101-based firmware)